Manage the Switch via the Device Manager Web Interface Chapter 4
On the Add/Edit Profile Instance window, you can configure the alarms and
actions for an alarm profile.
Field
Description
Name
A unique name for the alarm profile.
Alarm Name
These types of alarms can trigger an action.
DM Alarms
Alarm information appears on the dashboard of the Device Manager Web interface.
SNMP Trap
Alarm traps will be sent to an SNMP server, if SNMP is enabled on the Configure >
Security > SNMP window.
HW Relay
The switch's alarm relay is triggered, sending a fault signal to a connected external alarm
device, such as a bell, light, or other signaling device that you have configured.
Syslog
Alarm traps are recorded in the syslog. You can view the syslog on the Monitor > Syslog
window.