Data accessible with cip – Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual

Page 190

Advertising
background image

190

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

Chapter 5 Manage the Switch via the Studio 5000 Environment

To upload the EDS files directly from the switch over the network, follow these
steps.

1. From the Start menu, choose Programs > Rockwell Software >

RSLinx >Tools > EDS Hardware Installation Tool.

2. Click Add to launch the EDS Wizard and add the selected hardware

description and associated files.

Data Accessible With CIP

The CIP interface lets you access the following information:

Input data via I/O connection

Link status per port: not connected, connected
Unauthorized device per port: OK, not OK
Unicast threshold exceeded per port: OK, exceeded
Multicast threshold exceeded on each port: OK, exceeded
Broadcast threshold exceeded on each port: OK, exceeded
Port bandwidth utilization per port: value in %
Alarm relay major: OK, tripped
Multicast groups active: quantity

Output data via I/O connection

Port disable per port: enabled, disabled

Other status data

Switch internal temperature: degrees Centigrade
Power supply A present: yes, no
Power supply B present: yes, no
Identity information: vendor ID, device type, product code, product

name, revision, serial number

IOS release version
Switch uptime since last restart
Management CPU utilization: in percentage
CIP connection counters: open/close requests, open/close rejects,

timeouts

Port alarm status per port: OK, not forwarding, not operating,

excessive FCS errors

Port fault status per port: Error Disable, SFP error, native VLAN

mismatch, MAC address flap condition, security violation

Port diagnostic counters per port: Ethernet interface counters (10),

Ethernet media counters (12)