Manage the Switch via the Studio 5000 Environment Chapter 5

To configure general properties, follow these steps.

1. From the Module Properties dialog box, complete the fields described

below.

2. Click OK.

3. Go online with the switch by choosing Communications > Go online.

4. Double-click the switch to view the Module Properties dialog box.

5. Click Change.

Field

Description

Name

A name you choose for the switch.

Description

A description that helps you remember something important about the switch.

Ethernet Address

Choose one of the following:

Private Network—The private network on which the switch resides.

IP Address—The IP address you entered when you performed the Express Setup. The controller

uses the IP address to communicate.

Host Name—The host name provided on initial configuration when you performed the Express

Setup.The host name requires that you have a DNS server configured on the network for the
controller's Ethernet interface module.

IMPORTANT: Be sure that the IP address and host name are the same as those provided when you
performed Express Setup.