Global Macro
Once you complete Express Setup, as described on
, the switch executes a
global macro (ab-global). This macro configures the switch for typical industrial
automation applications that use the EtherNet/IP protocol. This macro sets
many parameters, including these major settings:
• Enable IGMP snooping and querier
• Enable CIP
• Configure QoS settings and classify CIP, PTP, and other traffic (does not
apply to switches with lite firmware revisions)
• Enables alarms, SYSLOG and SNMP notifications
• Enables Rapid Spanning Tree (RSTP), BPDU Guard, BPDU Filtering,
and loop guard
If you do not run Express Setup to initialize the switch, the global macro does not
run. You can use the CLU to run the global macro.