Global macro – Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual

Page 82

Advertising
background image

82

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

Chapter 3 Switch Software Features

Global Macro

Once you complete Express Setup, as described on

page 57

, the switch executes a

global macro (ab-global). This macro configures the switch for typical industrial
automation applications that use the EtherNet/IP protocol. This macro sets
many parameters, including these major settings:

Enable IGMP snooping and querier

Enable CIP

Configure QoS settings and classify CIP, PTP, and other traffic (does not

apply to switches with lite firmware revisions)

Enables alarms, SYSLOG and SNMP notifications

Enables Rapid Spanning Tree (RSTP), BPDU Guard, BPDU Filtering,

and loop guard

If you do not run Express Setup to initialize the switch, the global macro does not
run. You can use the CLU to run the global macro.

1783-BMS20CGPK

20-port (16 Ethernet ports; 2 SFP slots; 2 combo Gigabit ports)
managed switch; full firmware; PTP; conformal coating

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
2

Fa1/1
Fa1/2
Fa1/3
Fa1/4
Fa1/5
Fa1/6
Fa1/7
Fa1/8
Fa1/9
Fa1/10
Fa1/11
Fa1/12
Fa1/13
Fa1/14
Fa1/15
Fa1/16
Fa1/17
Fa1/18
Gi1/1
Gi1/2

Table 3 - Port Numbering (continued)

Cat. No.

Description

Port Numbering on Switch Labels

Port Numbering in config.text File

Advertising