145

Manage the Switch via the Device Manager Web Interface Chapter 4

Configure PTP Time
Synchronization

The IEEE 1588 standard defines a protocol, called Precision Time Protocol
(PTP), which enables precise synchronization of clocks in measurement and
control systems. The clocks communicate with each other over the EtherNet/IP
communication network. The PTP protocol enables heterogeneous systems that
include clocks of various inherent precision, resolution and stability to
synchronize. PTP generates a Master-Slave relationship among the clocks in the
system. All clocks ultimately derive their time from a clock selected as the
Grandmaster clock.

By default, PTP is disabled on all the Fast Ethernet and Gigabit Ethernet ports
on the switch.

The switch supports these Synchronization Clock modes:

• End-to-End Transparent mode—The switch transparently synchronizes

all slave clocks with the master clock connected to the switch.

The switch corrects the delay incurred by every packet passing through the
switch (referred to as residence time). This mode causes less jitter and error
accumulation than Boundary mode.

In End-to-End Transparent mode, all switch ports are enabled by default.

• Boundary mode—The switch becomes the parent clock to which the

other devices connected to the switch synchronize their internal clocks.

The switch and connected devices constantly exchange timing messages to
correct time skew caused by clock offsets and network delays.

This mode can eliminate the effects of latency fluctuations. Because jitter
and errors can accumulate in cascaded topologies, use this mode for
networks with only less than four layers of cascaded devices.

In Boundary mode, one or more switch ports can be PTP-enabled.

• Forward mode (default)—Traffic is forwarded through the switch (while

being prioritized by QoS) but is not acted on by the switch.

IMPORTANT

When changing the PTP timing message settings, remember that the system

does not operate properly unless all devices in the system have the same
values.