Chapter 2 Switch Installation

6. Insert the exposed part of the positive wire into the connection labeled

DC+ and the exposed part of the return wire into the connection labeled
DC-.

Be sure that you cannot see any wire lead. Only wire with insulation can
extend from the connector.

7. Use a ratcheting-torque screwdriver to torque the power connector captive

screws (above the installed wire leads) to 0.23 N•m (2.0 lb•in).

Do not exceed the recommended torque.

ATTENTION: An exposed wire lead from a DC-input power source can
conduct harmful levels of electricity. Be sure that no exposed portion of
the DC-input power source wire extends from the connector(s) or
terminal blocks.