Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual

Page 156

Advertising
background image

156

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

Chapter 4 Manage the Switch via the Device Manager Web Interface

6. In the Gateway Translation area, click Add Row, complete the fields, and

click Save.

The gateway translation enables devices on the public subnet to
communicate with devices on the private subnet.

7. (Optional). To configure traffic permits and packet fixups, proceed to

Configure Traffic Permits and Fixups on page 161

.

8. Click Submit.

Type

Choose one of these values:
Single—Translate a single address.
Range—Translate a range of addresses.
Subnet—Translate all of the addresses in the private subnet or a portion of the private subnet.

Range

Type the number of addresses to translate. This field is available only if you choose Range in the Type field.
Valid values: 1…128

Default value = 1
IMPORTANT: Each address in the range counts as one translation entry. The switch supports a maximum of 128 translation entries.

Subnet Mask

Type the subnet mask for the addresses to translate.
Valid values:

Class B: 255.255.0.0
Class C: 255.255.255.0
Portion of Class C:

255.255.255.128 (provides 128 addresses per translation entry)
255.255.255.192 (provides 64 addresses per translation entry)
255.255.255.224 (provides 32 addresses per translation entry)
255.255.255.240 (provides 16 addresses per translation entry)

Field

Description

Field

Description

Public

Type the default gateway address of the Layer 3 switch or router connected

to the switch’s uplink port.

Private

Type a unique IP address to represent the Layer 3 switch or router on the

private network.

Advertising