Rockwell Automation 1783-BMxxx Stratix 5700 Ethernet Managed Switches User Manual User Manual

Page 224

Advertising
background image

224

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

Chapter 5 Manage the Switch via the Studio 5000 Environment

6. Click OK.

7. Click the Public to Private tab.

Subnet Mask

From the pull-down menus, choose the subnet mask for the addresses to
translate.

Valid values:

Class B: 255.255.0.0
Class C: 255.255.255.0
Portion of Class C:

255.255.255.128 (provides 128 addresses per translation entry
255.255.255.192 (provides 64 addresses per translation entry
255.255.255.224 (provides 32 addresses per translation entry
255.255.255.240 (provides 16 addresses per translation entry)

Effective Private
Addresses

Displays the range of existing addresses for devices on the private subnet that are
configured for translation.
If blank, verify that the values in the fields above are valid.

Effective Public
Addresses

Displays the range of unique public addresses to represent the devices.
If blank, verify that the values in the fields above are valid.

Field

Description

Advertising