Troubleshoot the Switch

This chapter helps you resolve issues related to Stratix 5700 switches, as well as
perform common functions such as resetting the switch.

For additional troubleshooting, refer to the following:

Diagnose Cabling Problems on page 176

View System Log Messages on page 177

Verify Boot Fast

Boot fast failures are potentially fatal to the switch. Contact your Rockwell
Automation representative if your switch does not successfully complete boot
fast. You can disable the boot fast and run a power-on self test (POST) by using
the CLI.

IP Address Issues

These are some basic troubleshooting tips for issues related to the switch IP
address.

Topic

Page

Verify Boot Fast

235

IP Address Issues

235

Device Manager Web Interface Issues

236

Switch Performance

237

Access Direct Managed Mode

237

Restart or Reset the Switch

239

Recover the Switch Firmware and Restore Factory Defaults

240

Troubleshoot a Firmware Upgrade

241

Issue

Resolution

IP address is not received from DHCP server

If the switch does not receive an IP address from an upstream device operating as a DHCP server, make sure that the
upstream device is operating as a DHCP server and again follow the procedures to set up the switch in

Chapter 1, About

the Switches

.

Switch has wrong IP address

If the switch is installed in your network but you cannot access the switch because it has the wrong IP address, assign a
new switch IP address.

Refer to Access Direct Managed Mode on page 237

to assign the IP address, and then update the

switch IP address on the Device Manager Express Setup window.