198

Rockwell Automation Publication 1783-UM004E-EN-P - June 2014

Chapter 5 Manage the Switch via the Studio 5000 Environment

Table 30 - Switch Configuration Tab Fields

Field

Description

IP Address

This value must match the IP address on the General tab.

If you reconfigure your switch with a different IP address, you can lose communication with the switch when you click Set. To correct this problem,
you must go back to the Express Setup and General tab, set the new IP address, and download to the controller.

Subnet Mask

Enter the appropriate subnet mask for the switch. The subnet mask is a 32-bit number. Set each octet between 0…255. The default is
255.255.255.0.

Gateway Address

A gateway is a router or other network device through which the switch communicates with devices on other networks or subnetworks.

The gateway IP address must be part of the same subnet as the switch IP address. The switch IP address and the default gateway IP address cannot

be the same.
IMPORTANT: Communication is disrupted when you change the gateway (IP) address.

Primary DNS Server Address

Enter the IP address of the primary Domain Name Server (DNS). Set each octet between 0…255. The first octet cannot be 127 or a number greater
than 223.

Secondary DNS Server Address

Enter the IP address of the secondary Domain Name Server (DNS). Set each octet between 0…255. The first octet cannot be 127 or a number
greater than 223.

Domain Name

Enter the name of the domain in which the module resides. The domain name consists of a sequence of name labels separated by periods, such as
example.com. The domain name has a 48-character limit and is restricted to ASCII letters a…z, digits 0…9, and periods and hyphens.

Host Name

(Optional). Enter a name to help identify the switch when monitoring or troubleshooting a problem. The name can be up to 64 characters and can
include alphanumeric and special characters (comma and dash).

Contact

(Optional). Enter contact information for the switch, up to 200 characters. The contact information can include alphanumeric and special
characters (dash and comma) and a carriage return.

Geographic Location

(Optional). Enter a geographic location of the switch, up to 200 characters. The geographic location can include alphanumeric and special
characters (dash and comma) and a carriage return.

Spanning Tree Mode

Choose one of the following:
RSTP/MST
PVST+
RPVST+
RSTP/MST is the default.

Dual-Power Supply Alarm

Check the checkbox to enable the feature. The feature is disabled by default.

Refresh

Click to refresh the tab with new data from the switch.

Set

Click to save the settings to the switch and the SD card, if installed. Once the password has been entered correctly, changes can be made within 10
minutes without the Enter Password dialog box prompting you for a password.