Troubleshooting Your Ultra3000 Servo Drive

DriveHardFault

(Precharge Fault)

E35

The converter pre-charge cycle has failed.

DISABLE

NO

DriveHardFault

(Power Circuitry
Overtemperature)

E36

Excessive heat exists in the power circuitry.

DISABLE

NO

DriveHardFault

(AC Line Loss)

E37

One or more phases of the input ac power is missing.

DISABLE

NO

SERCOSFault

(SERCOS Ring Fault)

E38

The SERCOS ring is not active after being active and operational.

DISABLE

NO

DriveHardFault

(Self-sensing Commutation
Startup Error)

E39

Self-sense commutation fault detected.

DISABLE

NO

DriveHardFault

(230V Shunt Protection
Fault)

E40

Ineffective shunt resistor.

DISABLE

NO

DriveHardFault

(460V Shunt Protection
Fault)

E41

Ineffective shunt resistor.

DISABLE

NO

ConfigFault

(Motor Keying Error)

E42

The motor physically connected to the drive differs from the motor
specified in the user program.

N/A

NO

DriveEnableInputFault

(Drive Enable Input)

E43

Generated when Enable input switches off when drive is enabled.

DISABLE

Drive Enable Input

YES

DriveHardFault

(Unknown Fault)

E44

Lost motion fault

(only applies to applications with Stegmann feedback devices)

DISABLE

NO

SERCOSFault

(Duplicate Node Fault)

E50

Duplicate node address detected on SERCOS ring.

DISABLE

NO

RESERVED

All
Others

Software Fault Message

Error

Code

Description

Drive Fault
Action/Attribute

RSLogix 5000
Programmable
Fault Action?

RSLogix 5000

(Ultraware)