Apply power to your ultra3000 drive – Rockwell Automation 2090 Ultra3000 Servo Drives Integration Manual User Manual

Page 15

Advertising
background image

Publication 2098-IN005C-EN-P — March 2008

Commissioning Your Ultra3000 Drive

15

Apply Power To Your Ultra3000 Drive

This procedure assumes you have wired your Ultra3000 system,
verified the wiring, and are ready to begin using your Ultraware
software.

Follow these steps to apply power to your Ultra3000 drive.

1. Disconnect any load to the motor, making sure the motor is free of

all linkages when initially applying power to the system.

2. Apply input power to the Ultra3000 drive and observe the front

panel Logic Power status indicator.

3. Observe the front panel seven-segment status indicator on your

Ultra3000 drive.

ATTENTION

High voltage exists in ac line filters. The filter must be grounded
properly before applying power. Filter capacitors retain high
voltages after power removal. Before handling the equipment,
voltages should be measured to determine safe levels. Failure
to observe this precaution could result in personal injury.

ATTENTION

To avoid damage to the drive due to improper sequencing
of input power and the Drive Enable (Input 1) signal, do not
apply the Drive Enable signal without first applying input
power.

Status

Logic Power

If the Logic Power status indicator is

Then

ON

Go to step 3.

Not ON

1. Check your input power connections.

2. Repeat step 2.

Seven-segment
Status Indicator

Status

Do This

Actively cycling
segments in a full circle

The drive is ready.

Go to Detect Your Ultra3000 Drive
on page 16.

Flashing E followed by
two numbers

The drive is faulted.

Go to Error Codes on page 98.

Advertising
This manual is related to the following products: