Apply power to your ultra3000 drive with sercos, Step 2 – Rockwell Automation 2090 Ultra3000 Servo Drives Integration Manual User Manual

Page 81

Advertising
background image

Publication 2098-IN005C-EN-P — March 2008

Commissioning Your Ultra3000 Drive

81

Apply Power to Your Ultra3000 Drive with SERCOS

This procedure assumes that you have configured your Ultra3000-SE
drive and your SERCOS interface module.

Follow these steps to apply power to your Ultra3000-SE drive.

1. Disconnect any load to the motor, making sure that the motor is

free of all linkages when initially applying power to the system.

2. Apply input power to the Ultra3000-SE drive and observe the front

panel Logic Power status indicator.

3. Observe the front panel seven-segment status indicator on your

Ultra3000-SE drive.

ATTENTION

High voltage exists in ac line filters. The filter must be grounded
properly before applying power. Filter capacitors retain high
voltages after power removal. Before handling the equipment,
voltages should be measured to determine safe levels. Failure
to observe this precaution could result in personal injury.

ATTENTION

To avoid damage to the drive due to improper sequencing
of input power and the Drive Enable signal, do not issue
the Drive Enable command from RSLogix 5000 software
without first applying input power.

Status

Logic Power

If the Logic Power Status Indicator is

Then

ON

Go to step 3.

Not ON

1. Check your input power connections.

2. Repeat step 2.

Advertising
This manual is related to the following products: