Commissioning Your Ultra3000 Drive

Follow these steps to verify the number of indexing moves by using
drive signals.

1. Double-click the Monitor branch.

2. Click Setup.

3. Expand the Mode Configuration branch/the Indexing branch/and

check Batch Count.

4. Click OK.

5. Apply 12…24V dc to input 1.

Input 1 was configured as Drive Enable in a previous step.

6. Apply 12…24V dc to input 3 to the indexing move.

7. Double-click the Monitor branch and watch Batch Count count

down from 10 to 0.

8. Observe Outputs 2 and 3 for axis in dwell and in position.

9. Observe Output 4 when the Indexing move is complete.

10. Remove the 12…24V dc (Drive Enable) from input 1.