Rockwell Automation 2090 Ultra3000 Servo Drives Integration Manual User Manual
Page 74
Advertising

Publication 2098-IN005C-EN-P — March 2008
74
Commissioning Your Ultra3000 Drive
The New Module dialog opens.
4. Configure the new module.
a. In the Name box, name your file.
b. In the Slot box, enter the slot where your module resides.
c. From the Electronic Keying pull-down menu, choose an
electronic keying option (choose Disable Keying if unsure).
d. Check the Open Module Properties checkbox.
5. Click OK.
Your new module appears under the I/O Configuration folder in
the Explorer dialog and the Module Properties dialog opens.
6. Click the SERCOS Interface tab and reference the table below.
Logix SERCOS Module
Number of Axes
Data Rate
1756-M03SE or
1756-L60M03SE
Up to 3
4 or 8 Mbps
1756-M08SE
Up to 8
1756-M16SE or
1784-PM16SE
Up to 16
1768-M04SE
Up to 4