Publication 2098-IN005C-EN-P — March 2008

72

Commissioning Your Ultra3000 Drive

Configuring Your Logix SERCOS interface Module

This procedure assumes that you have configured the Ultra3000-SE
communication rate.

For help using RSLogix 5000 software as it applies to configuring the
ControlLogix, CompactLogix, or SoftLogix SERCOS modules, refer to
Additional Resources on page 8.

Configure Your Logix Controller

Follow these steps to configure your Logix controller.

1. Apply power to your Logix chassis containing the SERCOS

interface module and open your RSLogix 5000 software.

2. From the File menu, choose New.

The New Controller dialog opens.

3. Configure the new controller.

a. From the Type pull-down menu, choose your controller.

b. From the Revision pull-down menu, choose your

RSLogix 5000 software version.

c. In the Name box, name your file.

d. From the Chassis Type pull-down menu, choose your Logix

chassis.

e. Enter the Logix processor slot.

IMPORTANT

In order for the Ultra3000 drive to communicate with the
SERCOS interface module (indicated by the three status
indicators on the module going solid green), your RSLogix 5000
software must be version 11.0 or later.