Commissioning Your Ultra3000 Drive

3. Click the current setting and use the pull-down menu to change

the Operation Mode to Preset Position.

4. Close the Drive Branch dialog.

5. Expand the Mode Configuration branch and double-click Preset.

The Preset setup dialog opens.

6. Enter the Preset Velocity values as shown in the table above or

otherwise appropriate to your application.

7. Double-click the Digital Inputs branch.

8. Click the Value fields and use the pull-down menus to change the

input values as described below.