Commissioning Your Ultra3000 Drive

39

9. Using this table, determine the sequence of these three inputs that

correspond to the preset positions entered.

In this example, Preset Position 0 and 1 are configured so Preset
Select 0 is either off (Preset Position 0) or on (Preset Position 1).

10. Double-click the Monitor branch.

The (default) Drive Status parameters display.

11. Click Setup.

The Monitor Setup dialog opens.

Preset Selects

Binary Code

Selected Preset or Index

5

4

3

2

1

0

Select up to 64 locations via preselect inputs

5…0 by using BCD format.

(codes for preset selects 1 and 0 are shown)

0

0

0

0

0

0

Preset 0 or Index 0 is selected.

0

0

0

0

0

1

Preset 1 or Index 1 is selected.

0

0

0

0

1

0

Preset 2 or Index 2 is selected.

0

0

0

0

1

1

Preset 3 or Index 3 is selected.

1

1

1

1

1

1

Preset 64 or Index 64 is selected.