Collecting Performance Data Chapter 3

9. Click OK.

The new exception appears under Exceptions in the
Composite Time Patterns dialog box.

After you have created a plant model and a time pattern, and

associated the time pattern with activity areas in the plant, you can
set additional parameters that will be used to measure the OEE
rating and gather custom events for these activity areas.

FactoryTalk Metrics provides a great deal of flexibility in
configuring the parameters that will be used to measure the OEE
rating of an activity area. At a minimum, you must provide the
following information:

• The FactoryTalk Transaction Manager configuration that will

be the link to the control system.

• The amount of time it should take the activity area to produce

one good part (ideal cycle time).

• The control system counter keeping track of production

counts.