Collecting Performance Data Chapter 3

Since no shift information is collected, the reporting by shift is
not allowed.

Collect Scheduled Availability information from the

control system.

Select this option if shift schedule changes on the site are
frequent and variable.
With this option selected, both shift information and an

optional Scheduled Availability value are collected from the
control system and used to define availability.
You can configure the option in the following ways:

Select a data point to monitor for Shift information.

The data point should be an unscheduled numeric data
point that will contain the current shift number:

1. Click Select.

The Select Data Point dialog box appears.

2. Under Filtering Tools, in the FT Transaction

Manager Topic/Device list, select the device from

which you want to load data points.

3. At the top of the dialog box, click Refresh Points.

The Data Points area at the bottom of the dialog box is
populated with data points for the selected device.

Rockwell Automation Publication PLTMT-UM001M-EN-P-June 2014