Trace format tab, E 113) – Rockwell Automation FactoryTalk Historian SE ProcessBook 3.2 User Guide User Manual
Page 131

5
●
Visualize Data with Symbols
●
●
●
●
●
113
Legend
Check or clear options in this group box for displaying the tag name,
server name, description, value, and engineering units. Your choices
are reflected in the sample trend at the bottom of the dialog box.
The information that can fit in the legend is determined by the size of
the trend. Consequently, not all of the information in the legend may
be visible.
If the width of the legend is more than 50 percent of the width of
the trend, the legend does not display.
If the length of the text in the legend is longer than the total
height of the trend, the items on the bottom are not shown.
Display
Check or clear options in this group box. The sample trend reflects
the changes you make.
Plot Title
Vertical Scale Inside Axis
Draws the value scale inside the plot area.
Grids
Shows
grid lines
(page 123) on the trend.
Markers
When checked, markers indicate data points on the trend. If the
Markers box is not selected, three markers appear on each line to
help you match a line to a tag.
Trend orientation
Choose from the three options at the top of the dialog box to orient
your trend in a horizontal or vertical direction.
End Time at right (horizontal)
End Time at top (vertical)
End Time at bottom (vertical).
Trace Format Tab
Use the buttons on the Symbol Formatting (page 81) toolbar to configure
plot elements such as pens (traces (page 127)), text, and background.