Startup example – Rockwell Automation FactoryTalk Historian SE ProcessBook 3.2 User Guide User Manual

Page 338

Advertising
background image

FactoryTalk Historian ProcessBook User Guide

320

PB2TraceCompatibility Indicates whether all snapshot values are retained for trend

traces or discarded when a new archive event is received on

updating trends.

1 = Yes. Do not replace snapshot values when a new archive

event is received. This setting may result in a jagged trace that
gets smoothed when the trend is reverted.

0 = No. Use snapshot value filtering/removal logic so that only

archive values and any snapshot values since the last archive
event are shown on the trend.

EnableConnector
Attachments

Controls whether symbols drag and dropped on top of a
connector are made into connector attachments.

1 = true - allow.

0 = false - do not allow.

ConnectorsAvoid

Connectors

Controls whether connectors are treated as obstacles to be

avoided when performing object avoidance.

1 = true - connectors are avoided in object avoidance.

0 = false - connectors are not avoided in object avoidance.

AutoEnableScripting

When set to True, new dynamic symbols are automatically
enabled for scripting. If set to False, new dynamic symbols are

not automatically enabled for scripting. The False setting may
improve performance for very complex displays with many

symbols.

Startup Example

[Startup]
Startup ProcessBook=PIDEMO.PIW
DefaultFileLocation="C:\Program Files (x86)\Rockwell
Software\FactoryTalk Historian\PIPC\Procbook"
ModeBias=R
Retain Aspect Ratio=0
Symbol Library=SYMLIBRY.PIW
PromptForConversion=[PB_PROMPTFORCONVERSION]
Show Value Attributes=1
PB2TraceCompatibility=0
MakeBackupFile=0
ToolTipsEnabled=Y
Author=