System Administrator Notes

335

Marker Section

The Marker section of the .INI file maps the VAX trend markers to the
markers provided in FactoryTalk Historian ProcessBook:

[Markers]
NoMarker=9
Dot=0
SmallPlus=6
LargePlus=7
Asterisk=0
Circle=1
LargeX=8
Box=5
Diamond=3
BoxWithDot=4
DiamondWithDot=2
BoxWithDiamond=4

The values to the right of the equal sign represent these marker types in
FactoryTalk Historian ProcessBook:

0 = filled circle
1 = open circle
2 = filled diamond
3 = open diamond
4 = filled square
5 = open square
6 = filled triangle
7 = open triangle
8 = cross
9 = none

Display Section

The Display section in the .INI file specifies the supported terminals in
FactoryTalk Historian ProcessBook:

[Display]
Terminal Type=VT340