Minimum acceptance level, Reject threshold – Banner PresencePLUS Pro COLOR—PROII Camera User Manual

Page 111

Advertising
background image

Description

Field

If left unchecked (disabled), the Sensor will find a target shape that might have extra

edges. If checked (enabled), the Sensor will not find a target shape that has extra edges

of a specified length. The size of the minimum edge length is adjustable.

Extra Edges

Note:

If checked, the application will not allow a minimum edge length to be set

below the number specified for Minimum Edge Length (in the Input tab ) for this

tool.

If left unchecked (disabled), then the Sensor will find a target shape, even if it is missing

some edge content. If checked (enabled), then the Sensor will not find a target shape that

Missing Edges

is missing edges of a specified length. The size of the minimum edge length to check for

is adjustable.

Note:

If checked, the application will not allow a minimum edge length to be set

below the number specified for Minimum Edge Length (in the Input tab ) for this

tool.

Minimum Acceptance Level

This adjustment sets the acceptance level for pattern matches.
• Decrease the Minimum Acceptance Level to allow more variations in matching patterns.
• Increase the Minimum Acceptance Level to filter out patterns that contain small defects.
Percent match is a value between 20% and 100% that indicates the quality of the match (100% is a perfect match; 20%

is a slight match). The percent match can be used to detect large defects.

Note:

Banner does not recommend setting the Minimum Acceptance Level below 70%.

Reject Threshold

These adjustments allow the user to set the “band of gray scale values” the tool uses to determine the threshold when

Adaptive Threshold is specified.
If the Low is set to zero (default) and the High is set to 255 (default), then all gray scale values within the acquired

image are used to determine the threshold.
An example of narrowing the band of gray scale values is to set the Low at 50 and the High at 200. With these settings,

only gray scale values from 50 to 200 will be used by the Geometric Find tool to determine the threshold when

Adaptive

Threshold is specified.
These controls allow the user to “block” dark spots or light spots from influencing the threshold in the image acquired

by the Sensor.

111

Minneapolis, MN USA

Banner Engineering Corp.

PresencePLUS Software Tools

2/2010

Advertising