System Setup Dialog

This section describes how to configure the sensor and diagnose system errors in the System Setup window.

6.1 Sensor Select Tab

Use the Sensor Select tab to establish the Sensor connection with the PC.

Note:

An option box to open the Sensor Select tab is automatically displayed if the Sensor either is not connected

or is connected but with the wrong IP Address selected.

Sensor Neighborhood Fields

The Sensor Neighborhood will list sensors in your environment. The following describes the fields in the Sensor

Neighborhood.

Description

Field

If the Icon is green (Yes), the sensor is available; if yellow, a connection can't be established

for some reason; if red (No), the sensor is not available.

Available

Note:

The sensor to which you are currently connected will sho up as unavailable (red

icon).

The name of the sensor.

Name

The IP address assigned to the sensor.

IP Address

The sensor model and type.

Product ID

The sensor version.

Sensor Version

Indicates whether the sensor is running or not.

Running Inspection

Indicates whether there is an error condition associated with the sensor.

Error

The MAC address of the sensor.

MAC

PC (GUI) to Sensor Connection Setup

This selection is used to configure the communication link between the GUI (Graphical User Interface) and the sensor.

There are two possible selections, Ethernet (RJ45) and Serial:
Ethernet (RJ45)

This selection will configure the GUI to communicate with the sensor using the Ethernet (RJ45) connection. To

establish communication you must enter the IP address of the sensor you would like to communicate with into the

"Connection IP Address" edit box or select the desired Sensor from the Sensor Neighborhood results. Then, click on

the "OK" button to connect.

Serial

This selection will configure the GUI to communicate with a sensor via the Serial connection. To establish

communication you must first start Dial-Up Networking (DUN) on the PC. Then, click on the "OK" button to connect.