6.2.2 Remote Command Channel Configuration

This section describes the commands that are supported to communicate with a Vision sensor. All commands are

case-insensitive

Remote Command Set

All RCC commands are case-insensitive. Valid characters for commands are 7-bit ASCII alphabetic or numeric

characters (A-Z, a-z, 0-9), dash (-) and underscore (_).
All commands have the following structure:

ACTiON OBJECT_IDENTIFIER QUALIFIER(S)

ACTION

is an operation the user intends to perform on the OBJECT_IDENTIFIER. There are three possible actions

available:
• GET — used to retrieve information associated with the named object. This information can be a Boolean value, and

unsigned or signed number, a string or, for complex objects like the Communications tool, a field-delimited record

that includes other data types.

• SET — used to assign a value to a named object.
• EXEC — used to execute a pre-defined functional object or activity in the sensor. Activities may take object identifiers

as parameter qualifiers.

The table below identifies objects that are supported in the current RCC release, their identifiers, and the corresponding

actions that they will support. Items highlighted in bold are command keywords. Flag objects are appended with the
FLG

suffix, status objects are appended with the STS suffix, and counters are appended with the CNT suffix.

Banner Engineering Corp.