Banner PresencePLUS Pro COLOR—PROII Camera User Manual

Page 326

Advertising
background image

Comments

Optional
Qualifiers

Required
Qualifiers

Support Actions

Object or
Activity
Identifier

System Object,
Component, or
Activity

If no qualifiers are

specified, a 30

Timeout (msec)
or

None

EXEC

TRIGGER

Trigger

second timeout is

used.

NOWAIT

By default, a 30

second timeout is

used.

Timeout (msec)
or

NOWAIT

Numeric Inspection

ID

EXEC

PRODCHANGE

Product Change

Reset either the

System Error Flag,

None

SYSERRFLG

or

EXEC

RESET

Counter or Flag

Reset

Pass and Fail

PASSFAILCNT

counters, or

Missing Trigger

count.

or

MISSTRIGCNT

Enables remote

teach. If no

TRIGGER

or

TRIGGER

None

EXEC

RTEACH

Remote Teach

qualifiers are

NOWAIT

or

specified, remote

TRIGGER

Timeout (msec) teach will occur on

the next trigger. If

TRIGGER

qualifier is

specified, remote

teach will occur

immediately, and

the command will

block until a

default 30-second

timeout expires. If

TRIGGER

NOWAIT is

specified, remote

teach will occur

immediately, and

the command will

return right away.

If a timeout value

is specified, the

command will

block until the

specified timeout

expires.
Retrieve the sensor

online status.

None

None

GET

ONLINESTS

Online Status

Returns 1 if the

camera is ready, 0

otherwise

None

None

GET

READYFLG

Ready State

Banner Engineering Corp.