Description

Teach Screen Field/Button

stop the Teach process, and the Start/Stop button will

return to displaying Start.

The Sensor must receive an external trigger (pin 3) to

accept a sample.

Determines when information is updated on the PC.
Next Pass: Display the next passing inspection.
Next Fail: Display the next failed inspection.
Next: Display the next available inspection.
None: Do not display inspections.

Capture Control determines how often information is

updated on the PC.
Latched: Sets the Display option to None after an

inspection is displayed to prevent displaying additional

inspections.

Continuous: Continuously updates the inspection

information according to the display option.

Note:

The display may not capture every

inspection.

Image Enable: Determines if the image is included in

the result information. If checked, the inspection image

and results will update upon capture. If unchecked, only

the results will update upon capture.

Note:

Displaying the image on the PC will add to

the inspection time.

Teach Counts tracks the number of samples used in each

Teach process. Teach ignores samples that fail. Samples

fail for the following reasons:
• An Edge tool before the Test tool fails.
• A Locate tool before the Test tool fails.
• Measure tool fails to find two points.
• Time-out error.
• An ROI rotates or translates off the screen.
Click the Reset Teach button to clear all previously

gathered data.

Click the Start button to start the Teach routine.

Start

Click the Start button to stop the Teach routine.

Stop

When you click the Next button, the software prompts

you to save the inspection, and then it continues on to the

Run screen.

Next

335