The Measure tool window to the left shows the settings and results of the inspection to the right.
In the Inspection image, the center point of BLOB_1 and the nearest point in the input line MT_1 define the dashed

red line that runs from bottom left to top right. The actual measured distance between BLOB_1 and MT_1 is labeled

MT_2. The solid red triangle shows where MT_1 and MT_2 intersect. The Results section of the Measure Tool window

lists the distance between the intersection point and the Blob midpoint as 197.55 pixels.
The two shorter dashed lines represent the x- and y-components. The angle between MT_2 and the horizontal plane

is the curved counterclockwise arrow. In the Results section of the Measure Tool window, this angle is listed as -36.89

degrees.

Measurement Type

The PresencePLUS software can perform all three Measure tool operations using the default Absolute type or the

alternate Relative type. The types differ in how the Rotation Enable feature of a one of the Location tools—Locate,

Geometric Find, and Pattern Find—affect the Measure tool.

Absolute

When the measurement type is set to Absolute, the x- and y-components of the measured distance use the absolute, or
fi

xed, coordinate system of the camera’s field of view (FOV). If a rotation enabled Location tool precedes the Measure

tool in the order of operation (that is, if the Location tool is to the left of the Measure tool in the Navigation/Results

window), then the x- and ycomponent values and the angle of the line change as rotation occurs.