1 general troubleshooting – Banner PresencePLUS Pro COLOR—PROII Camera User Manual

Page 26

Advertising
background image

During powerup, all the controller LEDs illuminate for 15 to 20 seconds.


• After the Red Error LED turns OFF, verify that the Green power LED is flashing.

9. Launch the Software.

• Click Start > PresencePLUS to start the program.
• If the sensor has a different IP address than the default address (192.168.0.1), or if it is connected through a serial

connection, the following error message will display:

Sensor not found on specified IP address 192.168.0.1.

Do you want to try another IP address?

• Click Yes to access the System Setup window.
• Click on the Sensor select tab, and change the conection setup as follows:

Ethernet Connection

--

1. Select Ethernet (RJ45) in the drop-down menu.
2. Change the IP address to the address of the sensor to which the PC is connected.
3. Click OK.

Serial Connection

--

1. Select PC Serial in the drop-down menu.
2. Click OK.

3.3.1 General Troubleshooting

The following table describes solutions to the most common problems in using the

Presence

PLUS software. For further

assistance, contact Banner Engineering.

Cause/Solution

Problem

Sensor not getting enough power.

• Green Power LED on sensor is not ON.

• Check the connection to the power supply.

• Interface cannot connect to the sensor.
• No image on the monitor.

Run display set to "None"

• No image on PC or monitor.

• Ensure that the sensor is receiving trigger signals.

• Green Ready LED on sensor is OFF.
• The software seems to be working correctly, but the

image is missing.

Sensor not receiving triggers
• If the connections are secure, call a Banner Applications

Engineer.

Software restart needed or there are loose connections.

• Error message "Failed to capture a full-resolution image.

Please try again."

• Restart the PresencePLUS software.

Image is frozen on the PC and monitor.

Check all connections.

If a software restart does not correct the problem and the

connections are secure, call a Banner Applications

Engineer.

Green Ready LED on sensor is OFF

Ethernet connection lost.

• Error message "Failed to capture a full-resolution image.

Please try again."

• Reconnect the cable.

Image is frozen on PC, but image on monitor updates

properly.Image is frozen on PC, but image on monitor

updates properly.

Check the cable for breaks, then power down and back

up.

• Replace the cable.

Banner Engineering Corp.

Minneapolis, MN USA

26

2/2010

Getting Started

Advertising