Product change, 1 product change specifications, 2 product select input specifications – Banner PresencePLUS Pro COLOR—PROII Camera User Manual

Page 353: 3 proii product select, Chapter 11: product change, Chapter 11 product change

Advertising
background image

Chapter 11

Product Change

This section explains the Product Change ( line 15) input.
The Product Change input is used in conjunction with one of the four I/O points programmed as Product Select lines.

The inspection loaded will be executed following a valid trigger.
• The Product Change input responds to the leading edge transition of a pulse greater than 1 millisecond.
• The Product Select input is pulsed to correspond to a program location. For example, five pulses will load program

#5.

11.1 Product Change Specifications

Current Sourcing (PNP)

Current Sinking (NPN)

State

> 8V at -7.5 mA max.

< 2V at 1 mA max.

ON

< 2V at -7.5 mA max.

> 10 V at 4 mA max.

OFF

11.2 Product Select Input Specifications

Current Sourcing (PNP)

Current Sinking (NPN)

State

> 8V at -7.5 mA max.

< 2V at 1 mA max.

ON

< 2V at -7.5 mA max.

> 10V at 4 mA max.

OFF

11.3 ProII Product Select

The Pro II has four dedicated Product Select lines that can be thought of as making a BCD table. You can access

inspections 0-15 using the following pin combinations.

Product Select #0

Product Select #1

Product Select #2

Product Select #3

Inspection Number

OFF

OFF

OFF

OFF

0*

ON

OFF

OFF

OFF

1

OFF

ON

OFF

OFF

2

ON

ON

OFF

OFF

3

OFF

OFF

ON

OFF

4

ON

OFF

ON

OFF

5

OFF

ON

ON

OFF

6

ON

ON

ON

OFF

7

OFF

OFF

OFF

ON

8

ON

OFF

OFF

ON

9