2 rcc return values – Banner PresencePLUS Pro COLOR—PROII Camera User Manual

Page 328

Advertising
background image

Comments

Optional
Qualifiers

Required
Qualifiers

Support Actions

Object or
Activity
Identifier

System Object,
Component, or
Activity

Get the camera

exposure

None

Positive Number

SET

EXPOSURE

Exposure

Enables frame

number as

None

ENABLE

SET

FRAMETAG

Frame Number

Tag

command

acceptance

indicator
Disables frame

number as

None

DISABLE

SET

FRAMETAG

Frame Number

Tag

command

acceptance

indicator
Retrieve the status

of the frame tag

indicator

None

None

GET

FRAMETAG

Frame Number

Tag

8.7.2 RCC Return Values

RCC return values are numeric, and are listed below:
• 0 - command accepted. This return code is generated when a valid SET, GET, and EXEC command has been completely

handled by the sensor. It may be followed by a command-specific return value or a completion code.
If the frame tag is enabled, the current frame number will be returned instead of 0 as command acceptance indicator.

• -100 - Invalid command entered by the user.
• Trigger and Product Change error codes:

• -201 - Product change command attempted in the middle of the inspection
• -202 – Trigger command attempted in the middle of product change
• -203 – Trigger command is attempted when the inspection is not executing (sensor is idle)
• -204 – Specified inspection slot is out of range
• -205 – Trigger command attempted in the middle of the inspection
• -206 – Product change command attempted in the middle of a product change
• -207 – Product change command attempted while the sensor is in the Teach mode
• -208 – Product change attempted when the GUI is connected, and the inspection is not executing

• Comm tool error codes

• -301 – get/set tool command attempted while the inspection is not executing
• -302 – get command issued before inspection is triggered for the first time – tool results unavailable
• -303 – get/set tool command attempted in the middle of the inspection
• -304 – get/set tool command attempted in the middle of the product change
• -305 – Tool specified in get/set command not found in the inspection
• -306 – Requested comm tool is not configured for RCC
• -307 - Tool executed with an error or did not execute
• -308 - Specified tool operand is not a constant, and cannot be modified

• Reset command error codes

• -401 – Reset command attempted in the middle of the inspection
• -402 – Reset command attempted in the middle of the product change

Banner Engineering Corp.

Minneapolis, MN USA

328

2/2010

Communication Tool Setup

Advertising