Default IP Address

Socket

20,007

192.168.0.1

8

20,008

192.168.0.1

9

20,009

192.168.0.1

10

• The serial port is the RS-232 connector (Pins 1, 9, and 10) on the Sensor. The deafult settings for the serial port

are listed below.

Default Setting

Attribute

115200

Baud Rate

8

Data Bits

None

Parity

1

Stop Bit

None

Flow Control

3. Format the ASCII string of data (in the Format field).

• Choose a Delimiter and Start and End strings.
• Check the Enable Labels box to add the names for data being sent.
Allowable ASCII string options are shown below.

Note:

Start and End strings can now accept ASCII Hex values, and the following special characters: "\r",

"\n", "\t".

Description

Values

Option Name

The delimiter is used to separate the

individual pieces of data being sent.

, <Comma>
: < Colon>

Delimiter

The delimiter will follow every

; <Semicolon>

individual segment of data, including

start string and end string.

\r\n <CR_LF> Carriage return and

then line feed
\n\r <LF-CR> Line feed then carriage

return
\r <CR> Carriage return only
\n <LF> Line feed only

This option is a mechanism for

adding characters before a string of

data.

User-defined ASCII characters (limit

of 75 characters)

Start String

Note:

ASCII Hex characters are

allowed. Special symbols such

as \r, \n, and \t will cause a

carriage return, new line, and tab

to be output repsectively.