Operator’s manual, Auto sort, Auto configuration – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 105

Advertising
background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM CONFIGURATION / 97

AUTO SORT

At initial entry to the Module Configuration screen, the modules will appear
in random order and may not correspond with the actual mounting location
on the implement.

If modules are mounted on the implement by increasing serial number order
from left to right, pressing the Auto Sort button will group same module
types together and in the order the modules were mounted on the
implement.

After Auto Sort is performed, modules will appear on the Module
Configuration screen in groups by serial number order and module type.

IMPORTANT: The WSMT will always appear as Module Address 1 and

may need to be repositioned to correspond to its actual
mounting location after an Auto Sort.

To perform Auto Sort:

1. At the Module Configuration screen, press the Auto Sort button.
2. Verify that the module types and serial number have been sorted into

groups.

3. Change the WSMT address number to the correct module address

number as it relates to its mounting location on the implement. All other
modules types should be in correct order if modules were installed as
stated above.

4. Proceed to Auto Configuration.

AUTO CONFIGURATION

The Auto Config button is an automated method of configuring the
attached seed sensors and hopper sensors. To utilize the Auto
Configuration function, all sensors must be connected to the appropriate
modules in correct sequence.

Auto Config detects the following:

– the presence of seed sensors, hopper, and pressure sensors

connected to each module. The detected number of seed sensors
for each module automatically appears in the # of Rows data items
on the Seed Sensor Configuration screen.

– The detected number of hopper sensors are automatically entered

in the # of Hopp data items on the Hopper Sensor Configuration
screen.

– The detected number of pressure sensors are automatically

entered in the # of ACC data items on the Accessory Sensors
Configuration screen.

– Row #’s are automatically assigned based on the module address

of each module.

1. Press the Module Configuration button to access the Module

Configuration screen.

2. Press the Auto Config button. An hour glass appears in the upper

right corner while the system is configuring.

Advertising
This manual is related to the following products: