Operator’s manual, Rpm control setup – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 95

Advertising
background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM CONFIGURATION / 87

RPM CONTROL SETUP

The following constants on the Control Channel Setup screen define the
parameters for RPM Control.

Figure 53
Control Channel Setup - RPM Control

TYPE

Determines the control channel type as RPM control.

MATERIAL NAME

The Material Name displays only when a material is configured for the same
channel type.

CONTROL MODE

AUTO-Control channel is calculating application rates based on ground
speed and channel width under normal operating conditions.

MANUAL W/FEEDBACK-Overrides the current system when not operating
properly, i.e., faulty coil. Using the Increment/Decrement buttons from the
Main Work screen will set the RPM for the control channel. Manual Mode
with Feedback will show the actual RPM based on actual ground speed and
constants.

MANUAL W/O FEEDBACK-Overrides the current system when not
operating properly, i.e. bad feedback sensor. Using the Increment/
Decrement
buttons from the Main Work screen will set the RPM for the
control channel. No application rate feedback will display.