GRANULAR SEED AND FERTILIZER MONITOR
SETUP

The following constants on the Control Channel Setup screen define the
parameters for Granular Seed and Fertilizer Monitor setup.

Figure 51
Granular Seed Monitor

Type

Select Granular Seed Monitor or Granular Fertilizer Monitor as the channel
type.

Material Name

The Material Name displays only when a material is configured for the same
channel.

INPUT FILTER

The Input Filter provides a setting for the amount of filtering applied to the
flow meter feedback frequency of the control channel.

IMPORTANT: It is NOT recommended that the Input Filter be altered.

Any adjustments could result in the channel not
operating properly. If adjustments are made, a valve
calibration must be performed.

NOTE: The correct number of pulses

generated for one revolution
must be determined for sensors
other than DICKEY-john.

SENSOR CONSTANT

Sensor Constant establishes the number of pulses for one revolution of the
metering unit. If a standard DICKEY-john application rate sensor is used,
the value should be set to 360.0.