Operator’s manual – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 124

Advertising
background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

116 / SYSTEM CONFIGURATION

Figure 72
Manual Ground Speed

RELUCT FREQ

Used when ground speed is provided by a reluctance (2-wire) type sensor
connected to the actuator harness through an adapter harness.

DIGITAL FREQ

Used when ground speed is provided by a radar/digital (3-wire) type sensor
connected to the actuator harness.

CAN GROUND

Used when ground speed is provided by a radar/digital (3-wire) type sensor
connected to the cab harness or if radar/forward ground speed is
communicated on the CAN bus.

CAN WHEEL

Used when wheel speed data is communicating on the CAN bus. This
source does account for slip-like CAN ground.

NOTE: Manual ground speed can only

be entered if the source is
changed to MANUAL.

GSPD CONSTANT

Ground Speed Constant is the value representing the pulse count produced
by the ground speed sensor over a 400’ distance. Refer to Ground Speed
Calibration for additional information.

SHUT OFF SPEED

Shut Off Speed indicates the minimum ground speed allowed before the
system shuts off all control channels.

MINIMUM OVERRIDE

Minimum Override takes over when actual ground speed is below the
designated value. The control will operate at this speed until actual ground
speed rises above the minimum override speed or the actual speed drops
below the shutoff speed.

Advertising
This manual is related to the following products: