Operator’s manual, Flush enable, Flush – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 152

Advertising
background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

144 / SYSTEM OPERATION

FLUSH ENABLE

NOTE: Flush Enable will abort if the

button is pressed during a
Precharge state.

The Flush Enable feature is typically used to begin dispensing material at a
higher rate when the tractor is below shutoff speed, i.e. during startup or
turn around conditions. Material will dispense at the rate set at the ground
speed setup screen.

Flush enable is applicable to granular seeding, fertilizer, or liquid control
channels.

Reference System Configuration for control channel and ground speed
setup instructions.

Figure 87
Flush Enable (Main Work Screen)

Operating the Flush Enable function:

1. Ensure the master switch is turned ON below shutoff speed.
2. Press and hold the Flush Enable button to dispense material.
3. Release the Flush Enable button to stop dispensing material. Once

speed is above shutoff speed, flush is aborted and ground speed
based control will take over.

FLUSH

300

FLUSH

Press and hold
Flush to activate

FLUSH

Advertising
This manual is related to the following products: