98 / SYSTEM CONFIGURATION

IMPORTANT: Double check each sensor configuration to verify

correct numbering. RPM sensors must be configured
manually.

IMPORTANT: All sensors must be connected to the harnessing in the

correct sequence for AUTO CONFIG to operate properly.
Refer to the Installation Instructions accompanying each
module for correct installation.

To run Auto Config:

1. Press the Auto Config button. An hour glass appears in the upper

right corner while the system is being configured.

AUTO SORT AND AUTO CONFIG EXAMPLES

Figure 58
Auto Sort Examples

10245
10038
5000
10037
5001
10036

WSMT - PDC
WSMB - 18R
POM
WSMB - 18R
POM
WSMB - 18R

3
4
5
6

10245

10036

10037
10038
5000
5001

WSMT - PDC

WSMB - 18R

POM

WSMB - 18R

POM

WSMB - 18R

3
4
5
6

10245
10036
10037
10038
5000
5001

WSMT - PDC
WSMB - 18R

POM

WSMB - 18R

POM

WSMB - 18R

3
4
5
6

Before Auto Sort

After Auto Sort

Move WSMT after Auto Sort

Manually move

WSMT to

correspond with its

actual mounting

location.