Operator’s manual, Material setup constants - planter ctrl – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 46

Advertising
background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

38 / SYSTEM CONFIGURATION

MATERIAL SETUP CONSTANTS - PLANTER CTRL

Material setup parameters for Planter Control.

NOTE: Refer to Control Setup to link a

material to a channel.

Figure 28
Planter Control Setup Screen - Preset Method Disabled

TARGET RATE

Target Rate establishes the desired rate of application in KS (thousand)
seeds per acre or (KS/Ha).

MAX RATE

Maximum Rate establishes the maximum application rate in KS (thousand)
seeds per acre or (KS/Ha) that the control will allow. Target Rate cannot be
incremented to a value greater than this established Max Rate.

MIN RATE

Minimum Rate establishes the minimum application rate in KS (thousand)
seeds per acre or (KS/Ha) that the control will allow. Target Rate cannot be
decremented to a value lower than this established Min Rate.

INC/DEC %

The Increment/Decrement percent rate establishes the percentage of
change of the entered target rate that is applied each time the Material
Increment/Decrement
button is pressed on the Main Work Screen.

IMPORTANT: The Maximum or Minimum Rates may not be reached if

the % increase or decrease, based off the Target Rate,
exceeds the maximum or minimum rate limits set.

EXAMPLE: Maximum Rate is set for 101. Target Rate is set for 100. If the
% increase is set at 2%, the maximum rate of 101 will not be met because
the % increase of 2% would exceed the 101 maximum rate limit.

Advertising
This manual is related to the following products: