OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM OPERATION / 149

MANUAL OPEN OF CHANNEL

1. Press the Enable Manual Valve button to run the current selected

channel. This allows for manual open and close of valve position.

IMPORTANT: The Enable feature will only operate on the Diagnostics

screen.

2. If the Disable Manual Valve button is displayed, the selected channel

has already been enabled for manual valve position operation.

3. Set the Master Switch to the ON position.
4. Press the Increment button to open the channel’s valve. The Channel

Pulse Width Modulation (PWM) data item displays the current PWM
signal that is being output to the valve.

5. The Increment button must be pressed repeatedly to increase the

PWM signal to the valve. Each press will increase the signal by 2 hertz
(hz). The Channel Pulse Count and Channel Frequency Filter values
will display the current output of the feedback sensor.

6. Press the Decrement button to decrease the PWM signal and close

the valve. The Decrement button must be pressed repeatedly to
decrease the PWM signal to the valve. Each press will decrease the
signal by 2 hertz (hz).

7. The active channel is displayed in the button text.
8. Turn the master switch off to shutdown control channel.

SEED COUNT SCREEN

The Seed Count screen displays the number of seeds detected by each
sensor. Individual seed rows can be assessed and seed counts for those
rows may be accumulated. Up to 15 row numbers can display at one time.

Press the Seed Count button to display the Seed Count screen.

Figure 90
Seed Count Screen

Operating the Seed Count function: