Operator’s manual, Ground speed setup – Great Plains DICKEY-john IntelliAg Planter-Drill Control L3 User Manual

Page 123

Advertising
background image

OPERATOR’S MANUAL

IntelliAg PDC User 2 & 3

11001-1501-200811

SYSTEM CONFIGURATION / 115

GROUND SPEED SETUP

Ground Speed Setup determines:

• The input source and type of ground speed sensor
• The manual default ground speed (only displays when manual is

selected as source).

• Shut off speed
• Minimum override
• Ground speed constant
• Master switch timeout
• Ground speed fail alarm delay
• Implement Lift
• Precharge speed (displays only when the Precharge time is greater

than 0 mph (0 kmh) on a Control Channel Setup screen)

• Flush ground speed (displays only when Flush Enable is activated on a

Control Channel Setup Work screen, press the Speed Set button to
access the Ground Speed Setup screen.

Figure 71
Ground Speed Setup Screen

SOURCE

Source selects the type of ground speed sensor used and where the
sensor’s input is on the system.

MANUAL

Sets the system to operate using a constant, internally generated ground
speed. No ground speed sensor is required when using the Manual setting.
No area accumulation will occur when speed source is manual.

Manual Ground Speed can be used in the event of a failure of the ground
speed sensor being used. This is a constant, internally generated ground
speed that will cause the system to operate when the master switch is ON
at the speed that has been programmed. This value can be set to any
speed within the delivery capabilities of the system.

Advertising
This manual is related to the following products: