KEYENCE IV Series User Manual

Page 112

Advertising
background image

4-44

- IV Series User's Manual (Monitor) -

12

Tap the [Limit Adjustment] button.

The sensor turns to Test mode.

13

Image a high-quality-target and a low-

quality-target.

If the target is to be imaged using an external

trigger, input the external trigger.

If an external trigger cannot be input, tap the

button (Page 4-7) to image the target by

inputting an internal trigger temporarily. Imaging

by inputting an internal trigger finishes by the

button.

14

Adjust the threshold of anomaly detection

by checking the matching rate.

<Setting example>

If the matching rate of the high-quality-target is

higher than 90 and if the matching rate of the low-

quality-target is lower than 40, set the threshold to 65

which is an intermediate value between 40 and 90.

Matching rate

Threshold

y

A target is detected as OK if the matching rate is

greater than the threshold, and detected as NG

if the matching rate is lower than the threshold.

y

In accordance with status result of the tool,

the display color of the tool changes.

“Selecting a display method for tools” (Page 5-7)

y

The threshold can be changed using the

slider or by inputting values.

“Editing the value with the slider” (Page 3-14)

y

The thresholds can also be set in [Limit

Adjustment] of the Sensor Setup Menu screen.

“Adjusting Thresholds for Judgment” (Page 5-14)

15

Set the upper limit as needed.

“Setting the upper limit” (Page 4-46)

16

After the setting is completed, tap the [OK]

button.

The system returns to the main screen for the
Color Area/Area tool settings.

17

Tap the [OK] button.

The system returns to the main screen for tool
settings.

Outline tool

Color Area/Area tool

Position Adjustment tool

Extended functions

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)

Advertising