5-19

- IV Series User's Manual (Monitor) -

Tool Auto Tuning (Automatically Adjusting the Judgment Condition)

z

z

For Color Area tool (color type)

If the [AutoTune as OK] is tapped, the
information screen opens.
By tapping the [OK] button, the setup screen for
the color extraction area opens.
If the extraction area is inappropriate, tap the
color to be the reference of judgment, or tap the
[+]/[-] button and expand/reduce the color area
to be extracted.

y

By tapping the [Undo] button, the previous

operation can be cancelled.

y

To change the color of extraction target, tap

the [Clear] button and tap the color to be the

reference of judgment again.

After the setting is completed, tap the [Register]
button.
The auto tuning will be performed and the OK
or NG image will be displayed.

z

z

For Area tool (monochrome type)

If the [AutoTune as OK] is tapped, the
information screen opens.
By tapping the [OK] button, the setup screen for
the brightness extraction area opens.
If the extraction area is inappropriate, tap the
brightness to be the reference of judgment,
or operate the slider and expand/reduce the
brightness area to be extracted.

y

By tapping the [Undo] button, the previous

operation can be cancelled.

y

To change the brightness of extraction target,

tap the [Clear] button and tap the brightness

to be the reference of judgment again.

y

For details of settings by using the slider,

refer to “Editing the value with the slider”

(Page 3-14).

After the setting is completed, tap the [Register]
button.
The auto tuning will be performed and the OK
or NG image will be displayed.

5

Operating/Adjusting

Advertising