Status table – KEYENCE IV Series User Manual

Page 258

Advertising
background image

A-2

- IV Series User's Manual (Monitor) -

A

Status Table

Status table

Status

Monitor

screen

type

Sensor operation indicator light

Input

Output

PWR/ERR

OUT

TRIG

External

trigger

Switch

programs

External

master image

registration

Clear

Error

BUSY

Total Status / Total status NG /

Each tool / Each logic /

Pos.Adj.

*1

RUN

Error

Running

*2

Waiting for a trigger

RUN

Lighting

(green)

*3

OFF

¡

¡

¡

Í

OFF

*4

ON

OFF

Judgment processing

*5

*6

*7

*8

ON

Switching programs

*9

OFF

*10

*11

*12

Registering the external master image

*11

*10

Setting

Limit Adjustment

TEST

Blink

(green)

OFF

*5

¡

Н

Н

Н

Same

as while

running

OFF

OFF

OFF

Trigger Options, Master Registration, etc.

LIVE

Focus adjustment (MF)

OFF

*14

OFF

Automatically adjusting the brightness

Automatically adjusting the focus (AF)

Blink

(green)

OFF

*13

Í

*13

Setup Adjustment

-

*15

OFF

I/O Monitor

OFF

*16

Others

Н

Н

Н

Н

OFF

OFF

OFF

Error

Trigger error

Running

RUN

Blink (red)

Same as normal

Same as normal

¡

Same as normal

ON

Setting

LIVE

External master registration error

-

System error

Lighting

(red)

OFF

OFF

Н

Н

Н

Н

OFF

OFF

OFF

Startup memory readout error

*17

*17

*17

Status Table

¡

/Í indicates enable/disable of the input.

ON/OFF indicates the following status. The operation differs according to the output setting (N.O./N.C).

y

For N.O. ON : Indicates ON for an NPN or PNP open collector output.

OFF : Indicates OFF for an NPN or PNP open collector output.

y

For N.C. ON : Indicates OFF for an NPN or PNP open collector output.

OFF : Indicates ON for an NPN or PNP open collector output.

*1 Turns ON if the judgment is OK. Turns OFF if it is NG.

When the total status result is OK, the total status output turns ON.

When the total status result is NG, the total status NG output turns ON.

The total status conditions can be selected from [All Tools OK], [Any Tool OK] and [Logic 1] to [Logic 4].

“Total Status Conditions” (Page 4-65)

When the position adjustment is NG, the status of each tool becomes NG.

*2 The sensor continues running even during the operation of the [Monitor Settings/Sensor Image

History/USB Memory] screen in the run screen.

*3 Indicates the overall status result of the previous judgment process.

OK: Lighting (green), NG: Lighting (red)

*4 Outputs the status result of the previous judgment process.

*5 Lights (one-shot) by linking to the trigger issuance (external/internal).

When a trigger delay has been set, it lights before the delay.

Advertising