If an error targeted for clearing has occurred, outputting an error can be turned OFF by the clear error input.

Error output

Clear Error input

Min 2 ms

(Min 2 ms)

T5

(1)

(2)

ON

OFF

ON

OFF

Error occurred

(1) If an error occurred, the error output turns ON.

Error types which can be output are as follows.

y

System error

y

Startup memory readout error

y

External master registration error

y

Trigger error

To output the trigger error, set the trigger error in the Output Assignment (Page 4-60) under Settings
Navigator to [ON].

y

FTP error

To output the FTP error, set the FTP error within the FTP settings (Page 6-32) to [Enable].

(2) The error output can be turned OFF by the clear error input. Minimum ON/OFF input time is 2 ms.

Errors which can be cleared are as follows.

y

External master registration error

y

Trigger error

y

FTP error

The system error/startup memory readout error cannot be cleared.

y

For details on T5, refer to “Input Response Time” (Page 7-12).