Setting the upper limit, Setting the upper limit -46 – KEYENCE IV Series User Manual

Page 114

Advertising
background image

4-46

- IV Series User's Manual (Monitor) -

9

Select the cutting shape and tap the [OK]

button.

10

Set the position, size, and angle of the

cutting shape in accordance with the target.

Set clip shape

For details of editing the tool window, refer to

“Editing the tool window” (Page 3-15).

11

After the setting is completed, tap the [OK]

button.

The system returns to the screen to set the
mask region.

12

Repeat steps 2 to 11 as needed and set

the mask region.

13

After the setting is completed, tap the [OK]

button.

Area not be

masked

Masked area

The system returns to the screen to set the
[Window Shape] and [Mask].

z

„

Setting the upper limit

To perform the OK/NG judgment when an area of
the target is wider than an area of a high-quality-
target, perform the following procedures.

1

Tap the [Upper Limit] button.

2

Tap the [Enable] button for the upper limit

threshold and select the scale.

Select the scale in accordance with a range of
the matching rate required for judgment.

3

After the setting is completed, tap the [OK]

button.

The slider to set the upper limit and the lower
limit of the threshold will be displayed.

Outline tool

Color Area/Area tool

Position Adjustment tool

Extended functions

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)