3-4

- IV Series User's Manual (Monitor) -

Basic Operation Flow

Mounting, connecting, and wiring the sensor and monitor

Mount the sensor and monitor, and then connect and wire the cable.

“Chapter 2 Installation and Connection” (Page 2-1)

Turning on the power

Turn on the power of the sensor and monitor, and then perform the initial startup setting.

“Operation when the Power is Turned on” (Page 3-5)

Settings Navigator

Create the program to be used for operation in [Settings Navigator] (Sensor Setup).

STEP 1: Setting of image optimization

Set the image optimization for clearly imaging a target. Adjust the image for

defining the differences in the high and low-quality-target.

Set the trigger option, and adjust the brightness and imaging focus.

“1. Image Optimization (Clearly Image a Target)” (Page 4-6)

STEP 2: Registration of a master image

Image the high-quality-target and register the master image to serve as the

reference of judgment.

“2. Master Registration (Registering an Image as a Reference for Judgment)”
(Page 4-20)

STEP 3: Tool setting

Set the tool to judge a target.

Set the tool onto the master image and set the threshold for judgment. Up to 16

detection tools and 1 position adjustment tool in one program can be set.

“3. Tool Settings (Setting the Judgment Method for Targets)” (Page 4-28)

STEP 4: Output assignment

Assign the function to output to each output line (OUT1 to OUT4).

“4. Output Assignment (Setting Details of Outputting to Output Line)” (Page 4-60)

Starting the operation/adjustment

Switch the settings screen to the run screen, and start the operation. If the setting is
inappropriate, adjust the thresholds and tool settings (Tool Auto Tuning).

“Chapter 5 Operating/Adjusting” (Page 5-1)

Basic Operation Flow

3

Basic Operation