KEYENCE IV Series User Manual

Page 45

Advertising
background image

2-13

- IV Series User's Manual (Monitor) -

Cables

Wiring

color

Name

Assigning

default value

Description

Brown

DC24V

-

+ side of power

Blue

0V

-

- side of power

GND of input-output cable

Black

OUT1

Total Status (N.O.) Output assignable function

y

Total Status

y

Tot. StatusNG

y

RUN

y

BUSY

y

Error

y

Pos. Adj.

y

Judge result of each tool (Tool 1 to Tool 16)

y

Logical operation result of each tool (Tool 1 to Tool 4)

y

OFF (not used)

White

OUT2

BUSY (N.O.)

Gray

OUT3

Error (N.O.)

Orange

OUT4

OFF

Pink

IN1

External trigger ↑

Set external trigger.

Rising timing (↑) or falling timing (↓) can be set.

Yellow

IN2

OFF

Input assignable function

y

Program bit0 to bit4

y

Clear Error

y

Ext. Master Save

y

OFF (not used)

Light Blue IN3

OFF

Purple

IN4

OFF

Green

IN5

OFF

Red

IN6

OFF

Drain

FG

-

Insulated frame

Cable specification

y

Brown/Blue/Black/White/Gray/Orange : AWG25

y

Pink/Yellow/Light Blue/Purple/Green/Red : AWG28

y

With braided shield cable (with drain cable)

y

The output cable assignment can be changed.

“4. Output Assignment (Setting Details of Outputting to Output Line)” (Page 4-60)

y

N.O./N.C. can be changed.

“Output Settings” (Page 6-27)

y

The input cable assignment can be changed.

“Input Settings” (Page 6-26)

y

Individually insulate the non-used input-output cables.

y

For input cables of this sensor, connect with non-contact output (transistor output/SSR output).

For contact output (relay output), incorrect input may be operated due to the contact bouncing.