Extended functions for the output assignment, Extended functions items for the output assignment, Extended functions for – KEYENCE IV Series User Manual

Page 130: The output assignment -62, Extended functions items for

Advertising
background image

4-62

- IV Series User's Manual (Monitor) -

Extended functions for the Output Assignment

Extended functions items for the Output Assignment

Items

Description

Setting range

Default

value

Logic Settings

Assigns the logical operation

results of each detection tool to

the output function.

Up to 4 items, Logic 1 to 4, can

be defined.

y

Unused

The selected items are not used in

a logical formula.

y

Used

When the status results of the

selected items were OK, the total

status output function turns ON.

y

Used (Inverse)

When the status results of the

selected items were NG, the total

status output function turns ON.

Unused

Logic

Selects the logical operation

method of logics.

y

AND

Calculates the logical multiply

(AND) of all selected items.

y

OR

Calculates the logical sum (OR) of

all selected items.

AND

Total Status

Conditions

Selects a condition for the total

status result. The total status

result is displayed in accordance

with the selected condition.

y

All Tools OK

When all of the status results of the

detection tools was OK, the total

status output function turns ON.

y

Any Tools OK

When any of the status results of

the detection tools was OK, the total

status output function turns ON.

y

Logic 1 to 4

When the status result of the set

logic was OK, the total status

output function turns ON.

All Tools OK

Output Assignment

Extended functions

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)